The manufacturer claims the product to be white but it is really more of an off-white.CHV-THSTATW
Heating, Cooling and Relative Humidity Thermostat, White Faceplate
The CHV-THSTAT is a versatile heating and cooling thermostat with integrated humidistat designed for one- and two- stage control of forced air, radiant, and heat pump HVAC systems. Although functional as a standalone thermostat, the CHV-THSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron®. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.
Measurement Range
Indoor Temperature
0° to 110°F (-18° to 43°C)
Outdoor Temperature
-40º to 170º F (-40º to 77º C)
[1]
Humidity
0% to 100% RH
Temperature Tolerance
Over Full Range
±1ºF (±0.5ºC)
At Room Temperatures
±1ºF (+0.1/-0.4ºC)
Humidity Tolerance
±5%
Setpoint Range
Auto Setpoint
38° to 99°F (3° to 37°C)
Heat only Setpoint
38° to 89°F (3° to 32°C)
Cool only Setpoint
59° to 99°F (15° to 37°C)
Humidity Setpoint
5% to 70% RH
[2]
Relay Rating
1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
Power Requirements
24V
2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
Cresnet Power Usage
<1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet® communication only
Buttons
MODE
Accesses user controls - system mode, fan mode, humidifier, Crestron
®
system, and global update
VIEW
Accesses humidity reading, outdoor temperature reading
[1], system messages, and remote functions
UP
Selects user modes and increments selection in setup modes
DOWN
Selects user modes and decrements selection in setup modes
Display
Type
Transflective LCD, backlit
Size
2.75 in (6.99 cm)
Resolution
128 x 64
Viewing Angle
±50° horizontal (@0° vertical), ±50° vertical (@0° horizontal)
Displays current indoor temperature and relative humidity, outdoor temperature and relative humidity
[2]
, setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
Connectors
HVAC
(2) 9-position terminal blocks comprising the following:
Power Connections (Required):
24 (C):
24 VAC common terminal supplies remote 24 VAC power to thermostat;
24 (R):
24 VAC reference terminal – Can be connected to RH or RC by P4 jumper setting, or tied directly to power source
HVAC Control Connections (System Dependent):
HUM:
Energized to RHU during humidity call;
RHU:
Reference for humidifier;
RH:
Reference Heat – Used for calls to heating system;
RC:
Reference Cool – Used for calls to cooling system;
G:
Fan – Energized to RC during call for fan;
Y/Y1:
Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
Y2:
Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
O:
Changeover control – Energized to RC during cooling modes;
B:
Energized to RC during non-cooling modes;
W/W1:
Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
W2:
Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems
Remote Sensing Connections (Optional):
RSR:
Remote Sensor Returns – Common sensor terminal;
RS1:
Remote Sensor terminal – Connect the sensor from RS1 to RSR;
RS2:
Remote Sensor terminal – Connect the sensor from RS2 to RSR
NETWORK
(1) 4-position terminal block;
Cresnet slave port, connects to Cresnet control network
Enclosure
Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
Dimensions
Height
3.75 in (96 mm)
Width
5.00 in (127 mm)
Depth
1.04 in (27 mm)
Weight